ISS45      Release Table
     

Name of Link:  FTP Site for 8.1.4.0-060 Patch
  Code Distribution:   This release will be automatically applied to stores with the StoreNext Code Distribution System.
  POSTing Date:  29-May-09

ISS45 Version 8.1.4.0-060 Release Table

Last updated May 26, 2009

PLEASE NOTE: The new  fuel module PumpSrv 10.20.074 version 4.0.20.741  must be loaded in conjunction with the ISS45 8.1.4.0-060 software release in order to have a complete successful fuel environment.

See the Release Table below for a description of this planned release.

This table below describes the current plan for the new features and faults to be addressed in this scheduled software release.

Printing Instructions: many browsers do not support correct color and format printing directly from the Web.  For best results, with your cursor highlight the section of the table you wish to print and copy to the clipboard.  Then paste from the clipboard into a blank Word document and print the Word document to a color printer.

Enhancement or Fault Number

Item  Description

WD 11470

When accessing EJ on server too quickly you get an error. 

*Note* you have to wait about five minutes then try to access EJ again before it will open.  

Scenario:

1.Open EJ

2.Close EJ

3.Try to access EJ again within a short amount of time  

Expected Results: EJ opens without error.  

Actual Results: Get "-2147417818 Method '~' of object '~' Failed" error.

WD 11474

The buttons in the lower right section of WinPoS quit working if you scroll down past the 18th item in a PLU Group 

Scenario:

1.Build a PLU Group that contains more than 18 items

2.Define the PLU Group key in menusys.mac programming as FCODE = 919 in State = 10

3.On POST press the LOOK UP button and select the Group that was created in Step 1

4.Use the DOWN arrow button and scroll down past item 18, the last entry shown on the original screen

5.Try to select item 19 

Expected Results: Pressing the ENTER key will select and ring up the highlighted item 

Actual Results: The 16 keys in the lower right section of the screen no longer function and you must stop and re-start WinPoS to get the buttons working again

WD 14477

Telequip - Coin changer will not work 

Scenario:

1. Load Telequip OPOS drivers and tester on either a TP3K or TP2K

2. Connect Telequip T2+Flex via USB cable to TP3K or TP2K

3. Run Telequip tester and coin change does work

4. Make entry in post configuration - Sys. Admin\POS Setup\POS Config, E-Ticket-OPOS tab, OPOS Coin Dispenser Driver Name plus check in "Use OPOS Coin dispenser"

5. Restart WinPoS

6. Ring up $5.00 grocery and tender for cash of $5.05 to force coin changer to dispense a coin

7. There are no entries in the Peripherals.Log file to indicate that V8 recognized the existence of a coin changer on V8.1.4.0-050, V8.4.6 does have coin changer entries in the peripherals.log file

8. Some piece of code for coin changers is in V8.4.6 but has not been ported over to V8.1.4.0-050 

Expected Results: Coin changer should dispense change if change at end of order

WD 11539

Fixed in Fuel Module

PUMPSRV (4.0.20.741)

If the Registry entry MtxLinkServer\GeneralParameters\CheckForDiscountCoupon = 1

and swipe a credit card at the pump and answer to Gas Reward Voucher is No then $0.00 value is sent to MTX but it allows fuel to be pumped with no totals getting into the system. 

Scenario:

1.Set CheckForDiscount Coupon = 1

2.Swipe Credit Card at Pump

3.Answer No to prompt for Gas Reward Voucher

4.observe $0.00 value sent immediately to MTX

5.The transaction can be continued but no totals get into the system.

Expected Results: If no is selected you should continue but totals should be sent to MTX after the sale. 

Actual Results: If No is selected a $0.00 value is sent to MTX immediately.