Enhancement or Fault Number

Item  Description

 Fault 1704  There are no default IMG files available for selection during installation of FCC nor PumpSrv. These IMG files should be selectable during installation based on Fuel Pump Manufacturer selection.
Fault 1706  Incorrect receipt file installed for Gilbarco pump receipt
Is the default file usable by other Pump Manufacturers or is it custom to each.
This should be selectable during installation based on Pump Manufacturer and Model
 Fault 1712  Pure Products were configured in FCC, however, they are no longer synchronized in the ISS45 SQL table for FuelPureProducts. The Pure Products had to be manually added to the ISS45 Pure Products SQL table. The ISS45  "Grades to PLU" maintenance still relies on validation of FuelPureProducts SQL table data and would not allow us to perform Grades to PLU Maintenance without adding SQL FuelPureProducts table entries.
 Fault 1749  The FCC configuration contains a parameter to determine when to display the "Do you  want to print a receipt" prompt at the pump. The parameter is currently configured to display "before fueling". On debit transactions, the question does not show up until after fueling is completed. On credit transactions, the message displays at the appropriate time "before fueling".
 Fault 1786  Discrepancy Between Fuel Dispensed and Discount Amount on Loyalty Pay InsideCustomer Scans Loyalty Card at Pump
- Fuel prices drop by $.10 per gallon
- Customer selects 'Pay Inside' and pays $1.559 per gallon on Plus.
- Pump shows $5.00 and 3.210 gallons dispensed.
-Recall Receipt at POS
 Fault 1846  The ISS45 release 8.0.6_50 contains the payments fuel module called MTXLinkSrv.exe dated 8/27/03. This module doesn't appear to be functioning properly as it prevents the ISS45 fuel application from gaining an acknowledgment from the WinEPS payments software version 810.0.

When you select 'Pay Here Credit" at the Gilbarco pump simulator, the user swipes their credit card. The system then goes out to authorize the card. You never see the WinEPS system receive the payment authorization request to pre-authorize the fuel payment transaction.
 Fault 1847  After installing the ISS45 Fuel Version 8.0.6_50, it was discovered that the fuel promotions (both within ISS45 and at the pump) were not functioning. The price per gallon would not drop, and the fuel promotions within an order at the ISS45 POST were not being implemented as expected.
 Fault 1869  Fuel - file/record size of QDX 109 is incorrect. File number 109n is for PUMPSTAT needs to be increased from 200 to 600 to work properly.