ScanMaster      Release Table
     

Link to Update:  FTP Site for 2.2.0-060 Patch

Link to "The Patch":  FTP Site for "The Patch"
  Posting Date:  16-Aug-05


ScanMaster Version 2.02.00-060 Release Table 

See the table below for a description of the new features provided and faults addressed in this release. 

 

Enhancement or Fault Number

Item  Description

WD 6891

SM2SILPR.EXE

Extracting Movement is not working properly.

The Problem :

Under CONFIGURE, and the GENERAL OPTIONS tab, if the option "Add UPC Check Digit (During Movement) is unchecked during and EXTRACT movement in SIL, the MOVEMENT.LOG shows the wrong UPC numbers.

EX:

The MOVEMENT.LOG shows the UPC #802 4 times.  After running the SIL processor a UPC showing movement should only show in the MOVEMENT.LOG once.   

SM2SILPR.EXE

Extracting Movement is not working properly.

The Problem :

Under CONFIGURE, and the GENERAL OPTIONS tab, if the option "Add UPC Check Digit (During Movement) is unchecked during and EXTRACT movement in SIL, the MOVEMENT.LOG shows the wrong UPC numbers.

EX:

00000000000802,'BUNS SINGLE',13,0,0,0,0,0,1,0,,'0000',0.000,,,'BUNS

SINGLE',0.350,0,0,'A',0.00000,0,,0,0.000,875,306.25

,,0,1,0,0,0,0,0,0,0,0,'000',0,0,0,0,0,0,,,,,,,,,0,0,0,,,,,,0.350,,,0,,,,),

(00000000000802,'BAGELS',13,0,0,0,0,0,1,0,,'0000',0.000,,,

'BAGELS',0.450,0,0,'A',0.00000,0,,0,0.000,6934,2549.35,,

0,1,0,0,0,0,0,0,0,0,'000',0,0,0,0,0,0,,,,,,,,,0,0,0,,,,,,0.450,,,0,,,,),

(00000000000802,'DONUT SINGLE',13,0,0,0,0,0,1,0,

,'0000',0.000,,,'DONUT SINGLES',0.000,2,0,'B',0.00000,0,,0,0.000,8116,4058.00,,

0,1,0,0,0,0,0,0,0,0,'000',0,0,0,0,0,0,,,,,,,,,0,0,0,,,,,,0.000,,,0,,,,),

(00000000000802,'DONUT DOZEN',13,0,0,0,0,0,1,0,,'0000',0.000

,,,'DONUT DOZEN',5.990,0,0,'A',0.00000,0,,0,0.000,180,1078.20,

,0,1,0,0,0,0,0,0,0,0,'000',0,0,0,0,0,0,,,,,,,,,0,0,0,,,,,,5.990,,,0,,,,),

The MOVEMENT.LOG shows the UPC #802 4 times.  After running the SIL processor a UPC showing movement should only show in the MOVEMENT.LOG once.   

The check digit should be different for all of the above UPCs as well.  They should not all have a check digit of 2.

WD 6990

SM2SILPR.EXE

SIL Maintenance utility is not processing Host batches properly with alpha characters in the batch number field.

The Problem :

Host file sent by Warehouse has alpha characters in Batch# field.  When we process most or all batch headers are ignored and items are lumped in just a few batches.  This leads to confusion at store level as personnel have no guide as to batch contents for applying those batches.

Scenario:

1.If we take a SIL file provided by the warehouse and run it through the SIL Processor, (SM2SILpr.EXE, Ver 2.01.02.02) the processor does not break down the batches properly it does not accept Alpha/Numerics in the Batch number.  Our previous program ("PFT" version) would handle these batches without problem.

Expected Results: The SIL processor should create discrete batches identified and separated by individual batch numbers 

Actual Results: Batches are undefined and/or ignored altogether.